EMD GP7 - Wikipedia

The EMD GP7 is a four-axle road switcher diesel-electric locomotive built by General Motors Electro-Motive Division and General Motors Diesel between October 1949 and May 1954.. Power was provided by an EMD 567B 16-cylinder engine which generated 1,500 horsepower (1,119 kW). The GP7 was offered both with and without control cabs, and those built without control cabs were called a GP7B.

Chat Online
Indoor & Outdoor Wood Boilers - Heizomat Canada

Weight (kg): 1300 Water capacity (litres): 280 Flue diameter (mm): 200. PDF Specifications for HSK-RA 75; Brochure; RHK-AK 75 (Biomass) Rated Output: 75 kW / 255,000 BTU Continuous Output: 0 - 75 kW / 0 - 255,000 BTU Fuel: chip, pellet, sawdust, shavings, Rapeseed, straw, Miscanthus De-ashing: Chain & flight Heat Exchange Surface (m2): 7.20

Chat Online
Highly Efficient Meridian Condensing Boilers

Compact, versatile and highly efficient, Meridian Condensing Hot Water Heaters are packed with features that save on space, installation time and energy. Meridian Condensing Hot Water Heaters work at very high and constant efficiencies reaching up to 108.6% enabling seasonal savings up to 35%. For more details, check out our comprehensive guide

Chat Online
PDF 4.3 Applications of Energy Balance

4-26 Hot fl uid Cold fluid Hot fuid Cold fluid Parallel flow Counter flow Figure 4.4-3 Concentric tube heat exchangers. Shell-and-tube heat exchanger is the most common configuration. There are many different forms of shell-and-tube heat exchangers according to the number of shell-and-tube passes. A common form with one shell pass and two tube passes is shown in Figure 4.4-4.

Chat Online
PDF Chapter 7 Drying - Nzifst

Energy/kg water removed, as 2056 kJ are required to remove 0.778 kg of water, = 2056/0.778 = 2643kJ. Steam is often used to supply heat to air or to surfaces used for drying. In condensing, steam gives up its latent heat of vaporization; in drying, the substance being dried must take up

Chat Online
Chp 07 - LinkedIn SlideShare

Table 7.1. Minimum plate thickness for steam boilers. Boiler diameter Minimum plate thickness (t) 0.9 m or less 6 mm Above 0.9 m and upto 1.35 m 7.5 mm Above 1.35 m and upto 1.8 m 9 mm Over 1.8 m 12 mm Note: If the calculated value of t is less than the code requirement, then the latter should be taken, otherwise the calculated value may be used.

Chat Online
Convert btu per hour to horsepower | power conversion

1 btu per hour (btu/h) = 0.00039 horsepower (hp) Filed under: Main menu • power menu • Btu per hour conversion. Specific btu per hour to horsepower Conversion Results. #N#Enter a New btu per hour Amount to Convert From. * Whole number, decimal or fraction ie: 6, 5.33, 17 3/8. * Precision is how many digits after decimal point 1 - 9.

Chat Online
General Physics II - EIU

22.6 A particular engine has a power output of 5.0 kW and an efficiency of 25%. If the engine expels 8 000 J of thermal energy in each cycle, find (a) the heat absorbed in each cycle and 1 - [Q c /Q h] = e = 0.25 Q c /Q h = 1 - 0.25 Q c /Q h = 0.75 Q h = Q c /0.75 Q h = 8 000 J/0.75 Q h = 10 667 J

Chat Online
What Size Heater Do You Need? - Pool Heater Guide

Before you rush off madly spending money, it is a good idea to figure out what heating capacity you need for your swimming pool. Following the instructions following on this page you will be able to calculate the volume of a pool and work out a rough minimum heating capacity for your pool.

Chat Online
(PDF) Solution | Eskew Tade - Academia.edu

Academia.edu is a platform for academics to share research papers.

Chat Online
PDF c KEY ENGINEERING CONCEPTS - USP

336 Chapter 6 Using Entropy 6.3 Using the appropriate table, determine the indicated property. In each case, locate the state by hand on sketches of the T-y and T-s diagrams. (a) water at p 5 0.20 bar, 5s 4.3703 kJ/kg ? K. Find h, in kJ/kg. (b) water at 55p 10 bar, 3124.4 kJ/kg. Find u, in s kJ/kg?K. (c) Refrigerant 134a at 2 5 288C, xT 0.8. Find , in s

Chat Online
PDF F F=force in slack side - SOPEEC | www.sopeec.org

At entry to the superheater the dryness fraction of the steam is 0.96 and at the outlet the temperature is 250°C. The boiler burns coal at the rate of 700 kg/h, the calorific value of the coal is 31,500 kJ/kg and air is supplied at the rate of 17 kg/kg fuel. (a) Calculate the equivalent evaporation of the boiler plant per kg fuel from and at

Chat Online
automatic oil steam generator

If the overall boiler housing made of thick steel plate, it can also be made pressure (0.3 to 0.6 MPa) boiler, the boiler can more compact overall structure, used for gas - automatic steam generator in a combined cycle.

Chat Online
Calculate How Many BTUs are Needed to Heat Home - Inch

Locate your climate zone on the map above and provide your square footage and we'll determine how many BTUs your heating system should have. A British Thermal Unit, or BTU is a unit of measurement of energy. 1 BTU is the energy needed to heat 1 pound of water by 1° Fahrenheit. We often refer to the British Thermal Unit as a BTU, but the rating

Chat Online
PDF BAHR'UNO

LOW PRESSURE STEAM BOILER, THREE PASS REVERSE FLAME EFFICIENCY UP TO 97% OUTPUT RANGE from 94 kW (140 kg/h) to 2683 kW (4000 kg/h) TYPE STD HPO HP smooth pipe ESA pipe ESALU pipe FUEL gas, light & heavy oil gas, light oil gas DESIGN PRESSURE 0,98 bar DESIGN TEMPERATURE 119,6°C BAHR'UNO MODELS 140 160 200 300 400 500 600 800 1000

Chat Online
floating fish feed plant,feed pellet production line

Our floating fish feed pellet production line is the complete procedure of fish feed production including fish feed machine,fish feed crusher,fish feed mixer,fish feed dryer,and other equipment,This fish feed production plant is designed for making commercial pellets from corn, maize, grass, grains, protein, molasses and so on, and final pellets with different shapes, unique flavor, rich

Chat Online
10 t h water tube steam boiler - Water Tube Boiler

2t h water tube steam boiler - meubelstichting.nl. 2t h water tube steam boiler. Water-tube boiler - Wikipedia. A high pressure watertube boiler is a type of boiler in which water circulates in tubes heated Such watertube boilers in thermal power stations are also called steam generating units.

Chat Online
Mechanical Engineering Problems With Solution - DocShare.tips

Part - B: Engineering Mechanics (40 Marks) 6. Force : Concurrent Force system 7. Force : Non Concurrent force system 8. Force : Support Reaction 9. Friction 10. Application of Friction: Belt Friction 11. Law of Motion 12. Beam 13. Trusses. 104 141 166 190 216 242 265 302. Part - C: Strength of Materials (20 Marks) 14. Simple stress and

Chat Online
PDF Universal 500 - 1800 TC Also in product range

CERTECON and ECO SPI for Universal 500 - 1800 Size Steam capacity kg/h Method of combustion 1 80 - 120 Oil or gas 2 150 - 200 Oil or gas 3 250 - 400 Oil or gas Size Steam capacity kg/h Method of heating One size 135 / 160 Electrical 100 / 120 kW Steam generators ELEKTRO E 6 - 72 M series Size Steam capacity kg/h Method of heating

Chat Online
Kilowatts to refrigeration tons conversion - RapidTables.com

Kilowatts (kW) to refrigeration tons (RT) power conversion calculator and how to convert. One kilowatt is equal to 0.284345 refrigeration ton: So the power P in refrigeration tons (RT) is equal to the power P in kilowatts (kW) divided by 3.5168525:

Chat Online
BTU Calculator

BTU Calculator AC BTU Calculator. Use this calculator to estimate the cooling needs of a typical room or house, such as finding out the power of a window air conditioner needed for an apartment room or the central air conditioner for an entire house.

Chat Online
Generac Power Systems - What Size Generator Do I Need For

Call Us 1-844-242-3494 to Speak With a Customer Service Representative. This quick and easy Home Standby Sizing Calculator will provide you with 3 possible generators to fit your needs, along with estimated installation costs, and financing options. Just provide your zip code and how much of your home you want to back up (all of it or just

Chat Online
PDF Coal-Fired Performance and Cost

Above the Reheat Point of the turbine steam flow path. Boiler feedwater is pressurized with a single HP boiler feedwater pump (BFP), powered by an electric drive for the 400- and 600-MW cases and a steam turbine drive for the 900-MW case. For steam turbine-driven cases, the exhaust is directed to the LP turbine condenser.

Chat Online
PDF APPLIED THERMODYNAMICS TUTORIAL No.3 GAS TURBINE POWER CYCLES

the compressor is 10oC. The flow rate of air is 0.2 kg/s. The temperature at inlet to the turbine is 950oC. Calculate the following. i. The cycle efficiency. ii. The heat transfer into the heater. iii. The net power output. = 1.4 c p = 1.005 kJ/kg K SOLUTION 0.4 x 150.8 60.3 kW ( - ) 0.2 x 1.005 x (1223 - 472.4) 150.8 kW T 283 x 6 472.4

Chat Online
How Big of a Generator Do I Need to Run My Whole House?

In this case, you'd need at least a 25kW generator, since the starting wattage is 24,100W. Power your whole home. If you want to power just about everything in your home, your list would probably look more like this one: In this situation, you'd probably want at least a 35kW whole-home generator. Need a pro to help you find the right size

Chat Online
Calculator: Air Flow Rate through Piping | TLV - A Steam

Steam Flow Rate through Piping. Economical Insulation Thickness. Valves and Orifices. Cv & Kvs Values. Steam Flow Rate through a Valve. Steam Flow Rate through an Orifice. Condensate Load. From Piping at Start-up. From Heating Liquid (Continuous) From Heating Liquid (Batch) From Heating Air. From Radiant Heat Loss in Piping. Improved Steam Dryness.

Chat Online
How to Calculate the CFM of a Room | Hunker

Multiply the cubic volume of the room by the number of times you want the air to turn over or exchange in an hour. For example, if you expect the air to be exchanged twice per hour, multiply 2 times 640 to get 1,440. Divide your answer from step 3 by 60 to calculate CFM. In this example, you would divide 1,440 by 60 to get a CFM of 24.

Chat Online
3 Ways to Calculate BTU Per Square Foot - wikiHow

An 80% efficient furnace would deliver an output of only 80,000 BTU/h (100,000 x 0.8). To find an 80% efficient furnace that does provide enough power, divide the BTU/h rating you need by 0.8. So, 100,000 BTU/h ÷ 0.8 = 125,000 BTU/h, meaning you'd need a furnace rated to 125,000 BTU/h input.

Chat Online
API 5L Gr.B - BEBON steel

API 5L Gr.B steel plate/pipes, API 5L Gr.B steel plate/pipes, under API 5L standard, we can regard API 5L Gr.B steel plate/pipes as large diameter pipes.. API 5L Gr.B steel plate/pipes is one mainly of Steel for large diameter pipes,API-Gr.B steel is manufactured using premium grade of raw material. These are used to flow steam, water, oil and various petrochemicals substance in various

Chat Online
BTU Heating Calculator | Simplex Equipment Rental

Just divide your BTU needs by 64,000 or 94,000. A 300,000 BTU heater, temperature where the cylinders are located is -17°C. 300,000 BTU/64,000 BTU = 4,69 cylinders. Since the law prohibits connecting more than 4 tanks of propane to a single piece of equipment, using 100 lbs tanks is not recommended to get maximum output.

Chat Online
PDF Thermodynamics An Engineering Approach

cooling water at a rate of 145 GJ/h, determine (a) net power output and (b) the thermal efficiency of this power plant. Answers: (a) 35.3 MW, (b) 45.4 percent. 6-20 A steam power plant with a power output of 150 MW consumes coal at a rate of 60 tons/h. If the heating value of the coal is 30,000 kJ/kg,

Chat Online
PDF Superheated Steam Tables - Gilson Eng

Properties of Superheated Steam = specific volume, cubic feet per pound h g = total heat of steam, BTU per pound Pressure Lbs. per Sq. In. Total Temperature --Degrees Fahrenheit (t) Abs. P' Gage P Sat. Temp t 350° 400° 500° 600° 700° 800° 900° 1000° 1100° 1300° 1500° 15.0 0.3 213.0 3 h g 31.93 9 1216. 2 33.96 3 1239. 9 37.98 5 1287

Chat Online
steam boilers in egypt

new textile company in egypt gas steam boiler 5 ton. 4 ton diesel fired steam boiler project in malaysia. Perfect industrial steam boiler solution,industrial . 2019-3-20 · 02-26-2014 4 ton gas fired steam boiler for sale cost in Food processing Proven in the field over many years, 4 ton gas fired steam boiler is a cost effective solution for

Chat Online
(Pdf) Practice Problems for Engineering Thermodynamics

Two kg of water at 90 0 C is mixed with thr ee kg of water at 10 0 C in an isolated system. Calculate the chan ge of entropy due to the mixing process. [ C P f or water = 4.18 kJ/kg K ]

Chat Online
China Steam-Operated Single Effect Absorption Chiller

Steam-Operated Single Effect, Absorption Chiller, Air Conditioner manufacturer / supplier in China, offering Steam-Operated Single Effect Absorption Chiller, Integrative Solar Central Air Conditioner, Vacuum Boiler (VB-120) and so on.

Chat Online
Electric Steam Boiler 5 Ton Sg - Industrial Boiler

2019-11-15 · W = boiler capacity (Btu/h, kW) h g = enthalpy steam (Btu/lb, kJ/kg) h f = enthalpy condensate (Btu/lb, kJ/kg) m = steam evaporated (lb/h, kg/s) Boiler Horsepower - BHP. The Boiler Horsepower (BHP) is. the amount of energy required to produce 34.5 pounds of steam per hour at a pressure and temperature of 0 Psig and 212 o F, with

Chat Online
Steam Boiler 200 Kg H, 2 tons coal fired boiler

CONVERSION OF BOILER IN KG/H AND KW. CONVERSION OF BOILER IN KG/H AND KW (Approximate) G.B. and U.S.A. Steam from and at 100°C Boiler HP Kg/h 2.26MJ/kg Metric System Steam from 0°C to 100°C Kg/h 2.26MJ/kg Power In kW 1 5 10 15 20 30 40 50 60 70 80 100 150 200 250 300 350 400 450 500 550 600 650 700 750 800 15.65 78 156 235 313 470 626 783 940 1096 1252 1566 2350 3130 3915 4700 5480

Chat Online
What Size Heat Pump Should I Use for an 1800 - Hunker

Heat pumps come in BTUs, which stands for British thermal units. One BTU is the amount of energy it takes to raise a pound of water one degree. When the issue is an air conditioner or heater, the unit is measured in tons. Each ton of heating or cooling capacity is equal to 12,000 BTUs. So a 1-ton heat pump creates or absorbs 12,000 BTUs. A 2.5

Chat Online
40 CFR Appendix F to Part 75 - Conversion Procedures | CFR

3.3.4.1 For boilers, a minimum concentration of 5.0 percent CO 2 or a maximum concentration of 14.0 percent O 2 may be substituted for the measured diluent gas concentration value for any operating hour in which the hourly average CO 2 concentration is <5.0 percent CO 2 or the hourly average O 2 concentration is >14.0 percent O 2.

Chat Online
How to Determine the Required Size of a Tankless Hot Water

How to Determine the Required Size of a Tankless Hot Water Heater. Tankless water heaters come in two types, gas or electric. On average, gas-fired heaters are more efficient and heat the water

Chat Online